Why a sloping roof needs steps at a wall
A roof slope that ends against a wall leaves a long diagonal gap. The brickwork rises in level courses, the roof falls away at an angle, and water running down the face of the wall lands in the gap between them. The seal has to follow that diagonal, so it is built as a series of small steps, each one tucked into the wall at a different height.
Two parts make the seal. Under the roof covering, small pieces of lead called soakers turn the water back onto the tiles. Over them, a stepped flashing is let into the wall and laid down over the soakers. The soakers keep water out under the tiles; the flashing keeps it out of the wall joint. Neither does the job alone, and a leak at an abutment can be the failure of the partnership, not of one piece.
The same detail is used wherever a slope meets a rising wall: the side of a chimney stack, a gable wall that stands above a lean-to, a party wall between terrace roofs, or the cheek of a dormer. The principle is identical in every case, and the guides on lead dormer cheeks and lead flat roofs show the same upstand and chase on a different roof.
Because the diagonal is long, the detail is repeated many times along it. One loose step is a small fault. A line of them is a larger one, and the water that gets in at the top of the line runs down inside the wall and appears lower than the real fault, which is why a stain on a chimney breast can be a flashing problem several metres up.
Cutting and chasing the steps
Each step of the flashing is cut from sheet lead to follow one course of brick. The upper edge is turned into a joint in the wall, and the lower part lies over the roof covering. The pieces overlap, so water passing over one step lands on the next and never meets a gap.
The joint that takes the lead is raked out first. This is the chase: a groove cut in the mortar, along the line of each step, deep enough to hold the folded edge of the lead. The lead is pushed in, held with lead wedges so it cannot drop, and the chase is pointed over with mortar or a sealant matched to the wall. The wedges hold the lead and the pointing keeps the water out of the joint.
The wall may belong to someone else, and the law treats the work accordingly. The Party Wall etc. Act 1996 counts a flashing cut into a shared wall as party structure work, so the building owner must notify the neighbour at least two months before the date on which the proposed work will begin. The party wall guide covers who serves what and when, and a wall that is yours alone does not raise the point.
A chase can also be cut with a disc, which is quicker and cleaner than raking by hand. Either way the depth matters: too shallow and the lead pulls out, too deep and the wall is weakened. The detail is simple on paper and easy to get wrong in old, soft brickwork, where the mortar is crumbly and the wedge has little to grip.
Cutting in a stepped flashing
- Strip the old lead and loose mortar
- Rake out a chase on each step line
- Cut and fold each step to its course
- Wedge the folded edge into the chase
- Lap each step over the one below
- Point the chase to match the wall
What soakers do, and why tiles hide them
A soaker is a small piece of lead bent to an L-shape. One leg lies flat under a tile and the other stands up against the wall. There is one soaker for every course of tiles, each overlapping the one below, so that together they form a staircase running up the slope beside the wall.
Soakers sit under the tiles, which means they are invisible until the tiles are lifted. The stepped flashing above them is what you see. A soaker fails without showing it: the lead may crack where it is bent, the upstand may slump away from the wall, or a tile may have slid and pulled a soaker with it. Damp on the wall inside may be the only clue, with nothing wrong that can be seen outside.
Leadworx, a lead flashing maker, lists lead in codes 3 to 8 under BS EN 12588 and describes code 3 as "Soakers / Light duty", with code 4 as the standard choice for general flashing work. A soaker is a small piece that has to bend sharply, so a lighter code suits it. The code for each detail is set by the specification and not by habit, and a repair should say which has been used.
On plain tiles and slates, soakers interleave with the courses. On profiled tiles, a pantile for example, the ridges and hollows stop soakers lying flat, so the junction can be sealed with a continuous flashing dressed over the profile. Which method applies depends on the covering and is settled when the tiles are lifted at the survey. Ask what is being fitted when you read a quotation. New soakers, a new stepped flashing and fresh pointing are three separate parts of the work, and a price that names only one of them may leave the other two as they were. A thin line of detail in a quote is a reason to ask, and it costs less to ask before the roof is opened than afterwards.
Signs the abutment has failed
Abutment faults show up in three places: on the roof, on the wall and inside the house. On the roof, the signs are slipped tiles beside the wall, lead that has lifted or curled away and a stepped flashing with gaps in the pointing. On the wall, they are dark streaks below the flashing and mortar that has fallen from the chase. Indoors, they are stains along the line of the wall, patches of damp plaster and paint that blisters beside a chimney breast.
Several of the checks below can be made from the ground or from a window without a ladder, and a WhatsApp photo of the wall and the line of the flashing gives us something to examine before anyone climbs up. Take the picture in daylight, from straight on, with the whole line of steps in the frame if you can.
Only a survey in person produces a written price, because the roof has to be seen up close. It follows the water back to its source and takes in the whole roof, so a slipped tile, a blocked gutter or a tired chimney above the flashing is reported to you too. Reading the damp back along the wall is slow, careful work.
Signs to look for at a wall abutment
- Pointing dropped out of the chase line
- Lead lifted, curled or bent away from the wall
- Tiles slipped or cracked beside the wall
- Stains on the wall below the flashing
- Damp or staining on the room side
- Mastic smeared along the step line
Repairing steps and soakers
A step that has dropped can be re-wedged and re-pointed where the lead is sound. A cracked or thinned step can be replaced as a single piece. These are small repairs, and they suit a roof where the faults are confined to one stretch and the soakers below are in good order, which has to be seen, not assumed.
Where the soakers are cracked, missing or slumped, the repair means taking the tiles up beside the wall, stripping the old lead, checking the battens and underlay, and fitting new soakers course by course. It is a larger job, and it is the reason a quote for a flashing repair should say whether the tiles are being lifted.
A line of mastic over failed lead is not a repair, since it covers the gap and lets the lead go on failing underneath. Flat sealant over a stepped flashing has to be cut away before a proper repair can be done, so it adds to the work later. If you can see a smear of filler along the line of the steps, say so in a photo.
Alternatives exist for some details, including GRP and synthetic strips. The lead flashing alternatives guide sets out when they suit and when lead is still the right choice, and the lead roofing and leadwork page lists every guide in the group.
Scaffold, consents and what the quote covers
Stepped lead on the side of a chimney or a gable wall is high work, so the quote has to cover access. Scaffold, where a job needs it, sits inside the written total, and if it needs a licence for the pavement, we arrange the licence with our scaffolder. Our scaffolding guide explains that licence.
MyJobQuote's lead prices cover chimney leadwork and nothing else, so a wall abutment gets its written total from the survey. The number of steps, the height of the wall, whether tiles beside it must be lifted and the condition of the brickwork decide it. Ask any firm quoting for the same wall what its price includes, and whether the soakers are being renewed or only the visible flashing.
A listed building or a conservation area can change what is allowed at a chimney or a gable, since flashings change the look of the junction. Check with the council, or with the Broads Authority inside its executive area, before work starts. Removing a chimney breast always needs Building Regulations approval, which is a separate job from reflashing the stack that remains.
A repair confined to the visible lead leaves the cause behind. If the pointing has failed once, the wall beside the chase is probably soft, and re-pointing into soft brick fails again. The survey looks at the brick as well as the lead, so a step is not put back into a wall that cannot hold it.
Myth
A bead of mastic along the steps is a lasting repair.
Fact
It covers a gap; the chase and lead still need renewing.