Call 01493 277103

Roof replacement

Adding Roof Windows During a Re-Roof

When the old covering is already off, a roof window is easier to fit than on a finished roof. Here are the planning limits, the energy ratings and the published price.

Get a written quote

Call 01493 277103WhatsApp us

A roofer on scaffold photographing a chimney stack and flashings with a phone

The short answer

Yes, and a re-roof is a convenient moment, because the battens and underlay are already open. Roof windows come under permitted development Class C within set limits, and AD L 2021 sets 1.4 W/m²K for a roof window, with WER Band B as the minimum alternative. MyJobQuote gives an average of £1,100 for a standard mid-range Velux (22 September 2026).

Why the re-roof is the convenient moment

To fit a roof window the slope itself has to be opened: cutting through covering and battens, framing an opening between the rafters, then flashing the edges so water runs off and not in. On a finished roof that work disturbs a sound covering for the sake of one hole. During a re-roof the covering is already coming off, so the opening is framed at the same stage and the flashing kit is laid in with the new tiles.

MyJobQuote's page on Velux windows makes a related point about swaps: a straightforward swap of an existing window costs around £100 less, since a hole of the right size exists. The same logic applies a step earlier: a new opening formed with the new covering avoids a second round of scaffold and tile disturbance.

Position matters before anything is cut. A window needs headroom inside, clear rafter bays outside and a slope that is not already carrying a flue or a solar panel. The survey checks the loft side as well as the roof, so the glass lands where it will light the room and where the structure can take it.

Planning: Class C and its limits

Class C of the permitted development order takes in re-roofing and roof lights or windows, so a roof window on an ordinary house normally needs no planning application. Three limits apply. Nothing may stand more than 0.15 metres proud of the original slope, nothing may raise the roof's highest point, and chimneys, flues and soil and vent pipes fall outside the class altogether.

A window in a side slope carries a condition of its own: it must be obscure-glazed, and non-opening unless the part that opens is more than 1.7 metres above the floor of the room it lights. Obscure glass is needed whatever the height; only the non-opening rule relaxes at 1.7 metres.

Being in the Broads or a conservation area does not remove Class C, since only the Class B enlargement rights go on that land. An Article 4 direction can remove further permitted development rights, so the council is checked first, and a listed home needs listed building consent for anything touching its character. Flats have no householder rights. The planning guide covers each case.

Myth

In the Broads or a conservation area, no roof window is allowed.

Fact

Class C still applies there; an Article 4 direction or listing can change that.

Energy ratings and escape routes

Approved Document L (2021 edition, England) treats windows in a roof as their own item. Table 4.2 names 1.4 W/m²K for a replacement roof window, or WER Band B as the minimum rating, and 2.2 W/m²K for a rooflight. A thermal element in the regulations is a wall, floor or roof and does not include roof windows or roof lights. Band B is the minimum the table accepts.

The roof around it has its own number. Table 4.3 gives existing roofs a 0.35 threshold and an improved 0.16 W/m²K, and renovating over half the surface of a roof brings the entire roof into the upgrade where feasible. A re-roof can therefore lift the insulation while the window goes in. The insulating when re-roofing page covers the build-up.

If the window will serve a bedroom in a loft conversion, escape comes into it. Approved Document B paragraph 2.10 sets a minimum area of 0.33m2, a minimum height of 450mm and a minimum width of 450mm, and puts the lowest edge of the opening part at 1100mm above the floor at most. Our re-roofing for a loft conversion page covers the escape rules in full.

Roof window terms

  • Roof windowOpening window set in the roof slope
  • RooflightGlazed unit on a kerb, with its own 2.2 figure
  • WER Band BEnergy rating accepted as a minimum
  • Flashing kitMetal surround that seals the opening

What it costs and what the survey checks

MyJobQuote's Velux window page, dated 22 September 2026, says "Average cost for a standard mid-range Velux window is £1,100." That is a published average for a window, and it does not set the cost of framing the opening, the flashing or the finishing inside. Those depend on the size of the window, the covering around it and the structure beneath it, and they are the reason a figure for the window alone should not be read as the price of the job.

At Total Roofing Great Yarmouth every slope, ridge and flashing is surveyed, which is how a window position is judged against the rafters, the lead and the covering. If you want windows added, say so before the visit, because the one written total covers the re-roof and the openings together. A photo sent on WhatsApp to 07880 284133 helps us see the slope.

The roof replacement hub explains the wider job, and the Building Regulations for re-roofing page explains the route through building control.

Ask for the same detail from any firm you compare us with: which window, how the flashing is formed, what happens to the rafters and what finishing is included inside the room.

Questions and answers

Do I need building control approval to add a roof window?

A new opening changes the structure of the roof and falls under the energy rules in AD L, so check with the council's building control team or a registered building control approver before it is cut. At Great Yarmouth Borough Council or East Suffolk Council addresses, ask that council's team directly.

Is a roof window allowed in a side slope?

Yes, within Class C, but the window must be obscure-glazed, and non-opening unless the part that opens is more than 1.7 metres above the floor of the room. Both conditions apply to a window in a slope forming a side elevation. A front or rear slope does not carry that condition.

Is a rooflight the same as a roof window?

Not in the energy rules. For a roof window AD L 2021 sets 1.4 W/m²K, with WER Band B as the minimum alternative, while a rooflight is 2.2 W/m²K. Approved Document L treats a rooflight as a glazed unit on a kerb or upstand, standing out of plane with the roof, while a roof window lies in plane with the slope; which suits a roof is a question of design and of whether the glazing needs to open.

Get a written quote

Tell us about your roof

Hand dressing a lead ridge roll with a wooden bossing stick

10-year workmanship guarantee, in writing

Call WhatsApp Written quote