Flat Roof Skylights

A flat roof skylight is a rooflight on a kerb, not a roof window in a slope. Its weather performance depends on the kerb, the upstand, the membrane and the fall of the deck, and its glazing has its own figure under Approved Document L.

Get a written quote

Call 01493 277103WhatsApp us

An old brick workshop with a corrugated cement sheet roof and two rooflights

What a flat roof skylight is

On a pitched roof a window sits in the slope and the covering laps over its flashings. A flat roof offers no slope to lap over, so a skylight there is built differently. A rooflight is a glazed unit, flat or domed, mounted on an upstand called a kerb that stands above the surface of the roof. The waterproof membrane is carried up the outside of the kerb, and the unit is fixed and sealed to the top of it, so rain runs across the roof and past the unit and does not reach the opening.

Rooflights come as fixed units that do not open, and as opening versions, hinged or motorised, for ventilation. The glazing may be a single or multi-layer polycarbonate dome, a flat pane of glass, or a framed double-glazed unit. A walk-on glass panel is another version, set flush with the roof and made for foot traffic, though that is a specialist product and the load it carries is set by its maker.

Because a flat roof skylight sits low and wide, it brings a lot of daylight to a room below, which is why it is chosen for kitchen extensions, landings and bathrooms under a flat roof. The guide to types of roof window shows how rooflights compare with pitched-roof windows, and the roof lantern and sun tunnel guides cover the raised and tubular alternatives.

The detail that matters is the junction between the kerb and the membrane. That junction is where the weather performance of a flat roof skylight is decided.

Kerbs and upstands

The kerb is a low box built up from the roof deck, in timber or a purpose-made upstand, that raises the rooflight above the surface. Its job is to keep the glazed unit out of the water that sits on or runs across the roof. A unit set flush with a flat deck would sit in every puddle, so the kerb lifts it clear.

Upstand height is set by the membrane maker's own detail for the system used, so no single number applies to every roof. A kerb that is too low lets water splash up over the junction in heavy rain, and one that is too tall looks heavy and costs more. The kerb is insulated as well, since an uninsulated timber box through an insulated roof is a cold bridge and a place where condensation forms.

The membrane is dressed up the face of the kerb in one piece where it can be, with corners formed and not cut and butted, and it is finished under a capping or the rooflight's own flange. Where the membrane is felt, the corners are a hand-worked detail; where it is a single-ply sheet like EPDM, pre-formed corner pieces are used. In each case the weather seal depends on the dressing, not on a bead of sealant at the top.

A kerb is a small structure, and where an opening is cut into an existing flat roof, the joists have to be trimmed and the kerb carried on them. That is the same structural question as a pitched roof opening, with the same reason to put it to building control first.

Parts of a rooflight installation

  • Timber or purpose-made kerb on the deck
  • Insulation inside and round the kerb
  • Membrane dressed up the kerb face
  • Corner pieces or hand-formed corners
  • Capping or flange sealing the glazed unit

Falls, ponding and the unit in the way

A rooflight is an obstruction on a roof that is meant to drain. BS 6229:2025, as NFRC summarises it, sets a minimum 1:80 finished fall for general roof areas as well as internal gutters, and IKO reports that the code calls for a roof designed to 1:40 to reach 1:80 once built. A kerb sits across that fall like a dam, so water has to be steered round it.

One remedy is a small raised section, sometimes called a cricket, built on the uphill side of the kerb so that water splits and runs round both sides instead of standing against it. Without one, a pool collects behind the kerb, the membrane sits wet at the junction, and the seal is tested every time it rains. Ponding of that kind is a wear problem as well as a leak risk, since standing water ages most membranes faster.

BS 6229:2025 applies to flat roofs that use continuously supported flexible waterproof coverings: membranes of felt, EPDM or GRP, and not lead. The guide to flat roof falls goes further into how a deck is laid to falls and what ponding does.

When a rooflight goes into an existing flat roof, the existing falls are looked at as well as the position, using a level and a long straight edge across the deck. A rooflight placed in a low spot, or across a line that water follows, starts life with an avoidable problem. Moving it by a metre can matter more than any choice of glazing.

Myth

A rooflight on a flat roof is sealed with a bead of sealant.

Fact

The seal comes from the membrane dressed up the kerb; sealant only finishes the top joint.

Glazing, U-values and condensation

A flat roof skylight is a rooflight in the language of Approved Document L, which gives rooflights a limit of 2.2 W/m²K in Table 4.2. A roof window in a slope has a different limit, 1.4 W/m²K or Window Energy Rating Band B, so the product sold for a flat roof is judged on the rooflight line. Both are limits for heat loss: the lower the number, the less heat the unit lets through.

Multi-layer glazing, coated glass and insulated frames bring a unit under the limit. Single-skin polycarbonate domes, sold for sheds and outbuildings, are a poor match for a heated room, so the glazing is chosen for the use below it. A kitchen or a bathroom, where moist air meets a cold surface, needs a unit whose inner face stays warm enough that moisture does not run down the glass.

Condensation can be mistaken for a leak, and the distinction is simple: a leak appears after rain and follows the weather, while condensation follows the humidity and the temperature in the room. A wet ring round the inside of a rooflight on a cold morning, with a dry roof outside, points to the second. A short note on this is in the guide to leaking roof windows, and the fix is ventilation and a warmer unit, not sealant.

When the whole flat roof is renovated, the roof's own insulation figure applies too: a threshold of 0.35 W/m²K and an improved 0.16, where feasible. A rooflight installed during a re-roof is therefore part of a larger insulation question, and it is easier to settle both at once.

Where flat roof skylights leak

A leaking flat roof skylight is not necessarily a fault in the glass. Rain runs in at the upstand, the line where the kerb meets the membrane, or at the seal between the unit and the top of the kerb. The causes are few, and each can be seen from the roof.

A dressed corner can split where the membrane has been stretched or has aged, and a hairline crack at the angle can be a sign of it. A felt upstand can lift and open at its top edge when the bitumen dries out. The seal under an opening unit's sash can harden and shrink. A cracked dome lets water straight through. Ponding behind the kerb loads the junction with standing water, and what would be a minor weep in a well-drained roof becomes a steady leak.

Tracing a leak starts by working out whether it is a leak at all. Staining on the ceiling that spreads from the rooflight outward suggests water at the kerb. A drip at the sash suggests the seal. Staining that appears on cold mornings and fades by afternoon points to condensation. The guide to leaking roof windows sets out how each is told apart.

A repair that stops at the visible crack misses what caused it. If the upstand has failed because it is ponded, the cause is the fall; if it has aged out, the neighbouring flat roof membrane is likely to be near the end of its life too, and the survey looks at the whole roof, deck to gutter, not only the skylight and the patch of membrane beside it.

Where water gets in

  • Split or lifted corner on the upstand
  • Failed seal at the top of the kerb
  • Cracked dome or damaged pane
  • Water standing behind the kerb
  • Condensation mistaken for a leak

Fitting one, and how it ties to the membrane's life

A new rooflight in an existing flat roof means cutting the deck, trimming joists around the opening, building a kerb and dressing the membrane up it. It suits the moment when the membrane is being replaced anyway, because the new upstand can then be formed in one piece with the new covering, with no joint between old and new. Cutting a rooflight into an old membrane that has years of wear left is possible, but the patch is a weak point.

Lifespans bear on that choice, and HomeBuilding and Less give different ones. For EPDM, HomeBuilding gives 25-30 years and Less gives 30 to 50 years. For GRP, HomeBuilding gives 25-30 years and Less 25 to 40. For felt, HomeBuilding gives 10-15 years, while Less says torch-on felt lasts 10 to 20 years depending on quality and installation. Any skylight fitted into a membrane near the end of any of those ranges is worth pricing alongside a new covering.

The written price follows a survey of the whole flat roof, with the deck, the falls, the membrane and the upstands all looked at, and with scaffold or access dealt with as part of the one total. Where the roof sits over a pavement or road, scaffolding needs a highway licence from the county council; we arrange the licence with our scaffolder.

A photo of the existing roof and the room below, sent to WhatsApp, is a good way to start. The guide to skylights and roof windows links the rest of the cluster.

Questions and answers

Do flat roof skylights open?

Some do and some are fixed. A fixed unit lets in light only, while an opening one has a hinged or motorised sash for ventilation. Both sit on a kerb above the roof surface, with the membrane dressed up the outside of it, and the choice depends on whether the room needs air as well as light.

What U-value must a flat roof skylight meet?

Approved Document L 2021 sets rooflights at 2.2 W/m²K in Table 4.2. A roof window in a pitched slope has a separate limit, 1.4 W/m²K or Window Energy Rating Band B. The rooflight figure is the one a flat roof unit is judged on, and a lower number means less heat is lost through the glass.

Why does my flat roof skylight drip on cold mornings?

It may be condensation, not a leak. Moist room air meets the cold glass and runs down the inner face, and the roof stays dry outside. A leak shows after rain, at the kerb or the sash seal. Telling the two apart comes before any repair, and a photo on WhatsApp, 07880 284133, is a useful first step.

Is it better to fit a rooflight when the flat roof is recovered?

Yes, where the roof needs recovering anyway: the upstand can then be formed in one piece with the new membrane, with no joint to old material. Cutting into a membrane with years left is possible but leaves a patch at the weakest point, so the survey looks at the roof's age and falls before a position is chosen.

Get a written quote

Tell us about your roof

Hand dressing a lead ridge roll with a wooden bossing stick

10-year workmanship guarantee, in writing

Call WhatsApp Written quote