Centre-pivot windows
A centre-pivot window turns about a bar fixed across the middle of the sash, so the lower half swings into the room while the upper half swings out over the roof. The handle sits along the top edge, which means it is reached by lifting an arm above the head, and the view from the open window is clear above the covering, as the sash sits well clear of the line of sight.
The pivot has a practical advantage for cleaning. On models built for it, the sash rotates far enough for the outside pane to face the room, so it can be wiped from inside. That is useful on a roof that is awkward to reach, and it keeps a ladder off a steep slope.
What a centre-pivot window needs from the room is clear space beneath it. The lower half of the sash swings inward, so a bed, a desk or a stair rail within reach of that swing is a hazard, and a blind or a curtain needs a fitting that clears the arc. The sash also tilts out at the top, and that tilt changes the water-shedding at the head and is why the flashing kit has to be exactly right for the covering.
The pivot style suits a sloped ceiling where the window sits at a height that can be reached from the floor. It is a natural fit for a loft bedroom, a landing or a study, where the window is wanted for light and ventilation and a good view of the sky.
Top-hung windows
A top-hung window is hinged along its head, and the sash swings outward and upward like a canopy, with the handle at the bottom edge. Because the handle is low on the frame, it is easy to reach from standing height, and the arm of the window supports the sash in the open position. The result is a window that can be opened without the sash sweeping through the room.
That swing makes top-hung windows a good match for rooms where the space below the window matters: a bed head, a desk, a worktop, a staircase landing. The sash opens clear of the room, and the lower part of the window stays where it is. The shape of the opening also gives more shelter from rain than a pivot window, because the sash acts as a small awning over the gap while it is open.
Top-hung models also come in versions that can double as an emergency escape window. Approved Document B, in paragraph 2.10, describes an emergency escape window as having a minimum area of 0.33 m2, a minimum height of 450 mm and a minimum width of 450 mm, with 1100 mm as the highest the bottom of the openable part may sit above the floor. A sash that opens only a few degrees does not meet that, so the opening angle and the opening size both matter, and a window that is meant to serve as an escape is chosen for it.
Two ways a sash opens
Centre-pivot
- Turns about a middle bar
- Handle along the top
- Easy to clean from inside
Top-hung
- Hinged at the head
- Handle at the bottom
- Swings out and up
Conservation-style and low-profile windows
A conservation-style roof window is built to sit as flat as possible against the covering, with a slim frame, a central glazing bar and a dark finish, so that it resembles a traditional cast-iron skylight. The aim is to keep the look of an older roof when a new window is needed, and the frame is designed to lie close to the slope, not stand proud of it.
A flush window is a design choice and not a planning exemption. A conservation area, a listed home, the Broads and an Article 4 direction can each change the planning answer for a roof, and a listed home needs listed building consent whenever the work would alter its character as a listed home. Class C, the permitted development class that covers roof windows, has no exclusion for article 2(3) land, but an Article 4 direction, where one applies to the street, can bring a window on a visible slope under the council's control. Our planning permission guide for roof work takes the cases one at a time.
Conservation-style frames also come in finishes meant to age quietly, such as dark grey or black, which sits better against slate and clay than bright white does. A low-profile window is easier to match to a pitched slate or tile roof, because the frame lies within the line of the covering. It is also less likely to catch the wind, since it has no raised edge. On a roof where the look from the street matters, it is worth choosing a model whose frame is slim and whose finish is dark, and checking with the council before an order is placed.
Balcony and escape windows
A balcony window, sometimes called a cabrio, combines two sashes in one frame. The top sash lifts to open, the lower sash folds out to form a rail, and the result is a small balcony space with headroom on a sloping ceiling. It needs a larger opening than a standard roof window and a taller room beneath it, and it is a structural job: the opening is wide and long, so rafters are cut and a header and trimmers carry their load.
Because the sash projects from the roof when it is open, and because the window forms a different outline on the slope, the planning question needs checking with the council. Class C, which covers roof lights and windows, limits how far an alteration can protrude beyond the plane of the roof slope, at 0.15 metres, and a balcony window that opens out needs to be looked at against that and against the other conditions. A balcony window on a front slope is a different matter from one at the rear, since the front elevation is the one seen from the street.
Escape is its own question for a loft bedroom. Escape windows serve storeys up to 4.5 m above ground, and above that Approved Document B para 2.5 calls for either a protected stairway or an alternative escape route. A roof window can serve as the escape window for a room on the upper storey if it meets the size and sill figures in para 2.10. The building regulations guide for roof windows sets out where each rule applies.
Rooflights, lanterns and sun tunnels for flat and shallow roofs
A flat roof has no slope to carry a pivoting sash, so the glazing there is built differently. A fixed rooflight is a pane of glass or polycarbonate held in a frame on a kerb, a low upstand that lifts the unit above the waterproof covering. It lets in light and does not open, which suits a stairwell or a corridor where ventilation comes from elsewhere, and its lack of moving parts leaves fewer seals to wear. An opening version has a hinged section for ventilation. The guide to flat roof skylights covers the kerb, the upstand and the leaks that start there.
A roof lantern is a larger, raised glazed structure, with sloping sides and a ridge, set over an opening in a flat roof. It brings more light and more height than a rooflight, and it is a bigger structural and weatherproofing job. A sun tunnel is something else again: a small domed collector on the roof, a reflective tube through the loft and a diffuser in the ceiling, which brings daylight to a landing or a bathroom without a full-size window. Both have their own guides in this cluster.
Rooflights have their own regulation figure. Approved Document L 2021 gives rooflights 2.2 W/m²K and roof windows 1.4 W/m²K or a WER Band B rating, so the two are not interchangeable in the paperwork, and a product sold as a rooflight is not automatically a roof window.
Names for roof glazing
- Roof windowOpening window set in a pitched slope
- RooflightFixed or opening glazing on a kerb
- LanternRaised glazed structure on a flat roof
- Sun tunnelSmall dome and tube lighting a room
- KerbLow upstand a rooflight sits on
Matching the type to the room
The right type depends on the room beneath it. A landing or a bathroom can take a fixed unit or a sun tunnel where ventilation is dealt with by an extractor. A bedroom wants an opening window, and one that can serve as an escape where the room is on an upper storey. A kitchen or a study can use a top-hung window that opens clear of the worktop or desk, and the handle at the bottom of that style is within reach from a chair. A stairwell wants height, which a fixed window set high on the slope can supply.
The shape of the roof decides the type, as well as the room. A pitched slope takes a roof window, with the pitch range for the model checked against the slope. A flat roof takes a rooflight or a lantern. A conservation or listed roof takes the flush model and a conversation with the council first. In each case the covering decides the flashing kit, and the size of the window decides how much structure is touched, which is the point where price enters. The guide to skylights and roof windows gathers the rest, and the order of work for fitting any of them is laid out in the roof window installation guide.
If you are unsure, send a photo of the room and the roof on WhatsApp. A photo shows the pitch, the covering and what sits below, which is enough to talk through the types before a survey looks at the rafters.
Questions that pick the type
- Is the roof pitched or flat?
- What stands beneath the window in the room?
- Does the window need to serve as an escape?
- Is the home listed or in a conservation area?
- Does the room need ventilation or only light?