What a roof lantern is, and what it stands on
A roof lantern is a raised, glazed unit that sits over an opening in a flat or very shallow roof. From inside it looks like a small glass roof: sloping panes rise to a central ridge and draw daylight in well above the ceiling line. From outside it reads as a crown on the roof. A flat-roofed kitchen or dining extension is the natural home for one, because the opening can be sized to suit the room below it.
The lantern does not sit straight on the roof deck. It stands on a kerb, an upstand of timber or insulated board built around the opening and finished with the same waterproof layer as the roof around it. The kerb lifts the base of the glass clear of standing water, gives the frame something solid to fix to and marks the line where the roof covering meets the lantern. Nearly everything that keeps a lantern watertight is decided at that line.
A lantern is a different object from a roof window, which sits within the slope of a pitched roof, and from a sun tunnel, which is a tube. It also differs from the flat glass panel covered in our guide to flat roof skylights, because a lantern stands proud of the roof and has its own pitched glazing.
Lantern parts
- KerbRaised timber or board frame the lantern sits on
- Glazing barRafter-like strip that carries each pane
- RidgeTop line where the sloping panes meet
- CillBottom rail where the frame meets the kerb
- GasketFlexible seal between glass and frame
Where a lantern suits the roof and where it does not
A lantern asks three things of the roof underneath it. The deck must be strong enough to carry the kerb and the weight of the glass, the opening must be framed so that the loads go round it into the structure, and the roof must have a sound waterproof covering that can be dressed up the kerb. A flat roof that is already failing is a poor place to add a lantern, because the covering would have to be lifted around the opening and the lantern would be sitting on a repair waiting to happen.
Size is the other limit. The opening is cut through the deck and the joists around it are trimmed, so the span and spacing of those joists decide how large the opening can be without added steel or timber. The structure of your own roof settles that, and it is answered by looking at the joists, not by choosing a lantern from a catalogue and hoping it fits.
Think about the room too. Glass that rises above a south-facing kitchen collects heat on a bright day, and glass over a bedroom lets the light in at a time you may not want it. Solar-control glass and internal blinds are two answers, and our page on types of roof window shows where the other forms of roof glazing fit if a lantern proves bigger than the room calls for.
A lantern can also be fitted to a replacement roof. If the whole flat roof is coming up anyway, the kerb can be built as part of the new deck and covering, so the waterproofing is one continuous job and not a patch round a hole.
Aluminium and timber frames compared
Most of what you see of a lantern is its frame, and two materials dominate. Aluminium frames can be made with slim glazing bars, so more of the view is glass, and the metal is finished with a powder coating in a chosen colour. Timber frames bring a warmer look inside the room and can be painted or stained to match joinery. Each has its own demands.
Metal conducts heat. A plain aluminium bar would pass cold from outside to inside, so a good aluminium frame is built with a thermal break, a strip of insulating material separating the inner and outer metal. Ask what the thermal break is made of and where it runs, because a bar without one will be the first surface to mist up in winter.
Timber does not conduct heat in the same way, but it moves with the seasons and needs its finish kept up. A painted or stained timber lantern needs recoating when the finish wears, and a neglected surface lets moisture reach bare wood at the joints. Some timber frames are clad in aluminium on the outside to avoid that upkeep, which puts a metal skin on the weather side and wood on the inside.
Neither is the better choice in the abstract. Match the frame to the room and to how much upkeep you are willing to do, and read the maker's data for its own figures instead of relying on a general claim about either material.
Frame materials
Aluminium
- Slim bars, more glass
- Needs a thermal break
- Powder-coated colour
Timber
- Warm look inside
- Finish needs upkeep
- Can be clad outside
Glass, heat and the energy rules
A lantern is a large area of glass in a roof, so its thermal performance counts. Approved Document L (Conservation of fuel and power, Volume 1, 2021 edition) gives two different figures: 1.4 W/(m²·K) or Window Energy Rating Band B for a replacement roof window, and 2.2 W/(m²·K) for a rooflight. A lantern sits on its kerb out of plane with the roof, which is how the Approved Document defines a rooflight, so the 2.2 figure is the one that applies, worked out on the lantern's outer developed surface area.
Overhead glass has to be safe if it breaks. Glass units in a roof are specified with laminated or toughened panes so that a break does not drop shards into the room. The supplier states what its units use, and that specification belongs on your written quote and with the building control paperwork for the job.
Sealed glazing units are two or three panes with a gap between them, and the edge seal on each unit is what holds the gas or air in. When that seal fails, moisture gets into the gap and the unit mists between the panes. A mist inside the gap cannot be wiped away, because the glass is not dirty: the unit itself has failed and the unit is what needs replacing.
Glass that faces the sun can also be treated with a coating that cuts the heat entering the room. The coating changes how the glass looks from outside and how much light reaches the room, so ask to see a sample pane against the room's own light, not just a brochure.
Condensation: the damp that is not a leak
Wet glass inside a lantern gets mistaken for a leak, but it is a different fault with a different fix. Condensation forms when moist indoor air touches a surface colder than the air can stay damp at. A large area of glass, and especially a metal bar with no thermal break, is the coldest surface in the room, so that is where the water collects.
The look of the damp tells you which kind of problem you have. Beads or a film on the inside of the lowest pane point to condensation from room air. Mist trapped between two panes points to a failed edge seal. Wet timber or stained plasterboard around the kerb, and drips that start during rain rather than on a cold clear morning, point to a leak.
Kitchens produce plenty of steam, and a lantern over a cooking area collects it. Extraction above the hob and a vent that moves moist air out of the room reduce what reaches the glass. Trickle vents or an opening lantern light can help, but opening one part is a ventilation measure and does not make a poorly insulated frame warm.
A damp patch that grows after rain needs a different approach from steam on a winter morning, so do not treat the two alike. Send a photo of the glass and the ceiling to us on WhatsApp if you are unsure, and we will look at what it shows before anyone climbs up.
Reading the damp
- Film on the inner pane: room air condensing
- Mist between panes: failed edge seal
- Drips only after rain: a leak to trace
- Wet plasterboard at the kerb: leak or cold bridge
- Dry glass, damp ceiling edge: look at the roof
Where roof lanterns leak
Leaks cluster at junctions, because a lantern is a collection of joints. The most important one is the line between the roof covering and the base of the kerb. If the membrane is not dressed fully up the kerb and sealed where it meets the frame, rain runs behind it. Next come the glazing bars, where each pane meets the bar and a capping covers the joint. A cap that has lifted, a gasket that has shrunk or a screw head left unsealed gives rain a route in.
The ridge and the corner joints, where bars meet, are further places to look. Rain that gets in there can travel along a bar before it drips, so the stain on the ceiling may sit well away from the fault. That is why tracing a lantern leak starts with the whole unit and the roof around it, not with the nearest stain.
The roof under the kerb also matters. HomeBuilding gives flat roof lifespans of 25 to 30 years for EPDM, 25 to 30 for GRP and 10 to 15 for felt, while Less gives 30 to 50, 25 to 40 and 10 to 20 for the same coverings, so the two sources do not agree. Whichever figure you believe, a lantern on a membrane close to the end of its useful life will have to come off for the membrane to be replaced, so it is worth knowing the age and condition of the roof before the lantern is ordered.
Our hub page on skylights and roof windows sets out the full range of roof glazing and the faults that go with each.
Planning, Building Regulations and the quote
A lantern changes the outline of the roof. Class C of the General Permitted Development Order deals with changes to a house roof, and it carries a limit of 0.15 metres on how far work may protrude beyond the plane of the slope of the original roof. A lantern is designed to stand proud of the roof, so whether it can proceed without an application is a question for the council, or for the Broads Authority inside its executive area, and the answer also changes for flats, listed homes and any address under an Article 4 direction. Check before you commit to a design.
Building Regulations apply separately. Cutting an opening in the deck, trimming joists and adding a large area of glazing are matters for the council's building control team or a registered building control approver, who will look at the structure, the thermal figures and the safety of the glass. Our guide to Building Regulations for roof windows goes through the rules that apply to roof glazing generally.
When we survey for a lantern we look at the whole flat roof, not just the place where the opening will go: the deck, the covering, the falls, the outlets and the edge details. BS 6229:2025 sets a minimum finished fall of 1:80 for membrane flat roofs, and a lantern kerb that blocks the water's path across the roof can create a pond on its high side. Whatever else the survey turns up on that roof gets reported to you in plain words.
What you receive afterwards is a written quote with a single total price. It is not a catalogue figure for the lantern alone, since a lantern's cost depends on the opening, the kerb, the roof around it and the glass specification. A lantern's price swings with the opening, the kerb and the glass, so the figure is fixed once the survey is done.