The short answer
A tiled roof with a cold loft needs ventilation, and with a high-resistance underlay Marley gives 25 mm along the eaves at 15 degrees or less and 10 mm above 15 degrees. A warm roof needs none, according to CNC's guide. Which case your roof falls into depends on where the insulation and the underlay sit.
Why a loft needs to breathe
Warm air from a house carries water vapour. Some of it climbs through the ceiling into the loft, and in cold weather it meets the cold underside of the covering, where it can condense into droplets. Left alone, those droplets soak timber and insulation and can drip back onto the ceiling.
Ventilation gives that vapour a way out before it turns to water, which is why an eaves gap, a ridge vent or a ventilated tile is built into a roof. The guidance that sets how much is BS 5250, which deals with moisture in buildings. The 2021 edition is listed as current and under review.
The amount depends on the construction. A roof with its insulation at ceiling level and a cold loft above is a cold roof. A roof with insulation in the rafters, so that the loft space is kept warm, is a warm roof. The two are treated differently, and so is each type of underlay.
The published eaves gaps
Marley's page on ventilating a cold roof gives figures for each underlay. They are repeated here in a table.
| Underlay | Pitch | Opening |
|---|---|---|
| High resistance (HR) | 15 degrees or less | 25 mm along the eaves |
| High resistance (HR) | More than 15 degrees | 10 mm along the eaves |
| Low resistance (LR) | Well-sealed ceiling, air-permeable covering | 3 mm at the eaves, or 5 mm at the ridge |
The last row carries conditions. Marley describes the 3 mm eaves gap as fortuitous ventilation through normal eaves construction, provided the UKAS third-party certification requirements are fully met, or 5 mm of opening at the ridge, or higher up the roof, as an alternative. Each figure is a floor taken from the maker's page, so the product literature for the underlay still decides.
Vapour cannot pass through a high-resistance underlay, and that is why it comes with the larger eaves gap. Low resistance and air permeability are separate qualities: the air permeability in that last row belongs to the covering, not to the underlay.
Warm roofs and what the council says
A warm roof has its insulation between or above the rafters, leaving the vapour no cold space to reach. CNC Building Control's guide to warm roofs says of that type that no ventilation is required, and of a cold roof that ventilation is required. Its author, CNC Building Control, serves South Norfolk, Norwich City, Broadland, King's Lynn & West Norfolk and Fenland as a partnership of five councils. For other addresses, treat the guide as a reference only.
That is the reason a loft conversion or an insulation upgrade needs thought. Adding insulation to a cold loft without keeping the ventilation path can make condensation worse, and turning a cold roof into a warm one changes which rules apply. Settle it with the building control team before work starts, and for changes to a roof the Planning Portal's guide points the same way.
Marley's wording for tile fixings is a reminder that no single figure fits every roof: its guidance describes a specification written for the site. Ventilation works the same way. The table gives the published gap for each underlay, and the roof itself decides whether it is met.
Signs a loft is not clearing, and what the survey checks
A loft that is not ventilating shows it in a few ways, most of them visible only from inside:
- Dark spots or a furry growth on rafters, felt or the underside of the boards.
- Damp insulation, or insulation that has compacted and stayed wet through a dry spell as well as a wet one.
- Droplets or frost on the nail points that come through the covering.
- A musty smell in the loft, or a ceiling stain with no matching leak.
These signs can also come from a leak, so the cause is separated before anything is changed. At Total Roofing Great Yarmouth a survey follows the air path from the eaves through the loft to the ridge, looks at the underlay and checks that insulation has not blocked an eaves gap. Our quote after the visit is one written total, set once we have seen the loft and the roof.
For the layers under the tiles, see roof underlay and battens, and for the rest of the service the pitched roofing page.