Two ways to build a flat roof
Every flat roof has the same parts: joists, a deck, a waterproof covering and, between the room and the sky, insulation. What differs is the order. Above the deck and directly beneath the waterproof covering is where a warm roof keeps its insulation. A cold roof puts it below the deck, between the joists, and leaves an air gap above it.
The names describe the deck's temperature. With insulation above it, the deck and joists stay close to the temperature of the house. With insulation below it, the deck takes on the temperature of the weather. That single difference drives most of what follows: ventilation, condensation, thickness and cost.
A third build, the inverted roof, puts the insulation on top of the waterproof layer, with ballast or paving over it. It is used on roof terraces and some commercial roofs, and it is outside the scope of this page. Our flat roof replacement guide covers the stages of a full strip and re-lay, and this page deals with the choice of build-up that goes into it.
The choice is made once, at design, and it is hard to change later without lifting the roof. It also reaches into the rest of the building: the height of the roof edge, the depth of the ceiling, the position of lights and the route that moist air takes out of the house.
Where the insulation sits
Warm roof
- Boards over the deck
- Deck stays near room heat
- No ventilation gap
- Edge sits higher
Cold roof
- Insulation between joists
- Deck sits outside the insulation
- Ventilated void above
- Edge stays thin
How a warm roof is built
A warm roof is built from the deck upwards. A vapour control layer is spread over the deck, rigid insulation boards are laid over that, and the waterproof covering is finished across the boards. The vapour layer stops moist air from the room reaching the cold underside of the insulation. Boards are laid with their joints offset, and the fall is formed in them with tapered boards, so the covering sits on a sloping surface.
Because the insulation is above the deck, the structure stays warm and dry. There is no void to ventilate, no air path to keep clear and no risk that a blocked vent stops the roof working. The ceiling below can be fitted with its own lights and plasterboard, and the joist depth is left free for services, since the insulation does not have to fit between the joists.
The cost of that is height. The insulation boards add thickness above the deck, and so the finished roof edge sits higher than in a cold roof. That can matter at a junction with a window head, a door or an existing eaves line. Planning for the height of the build-up before ordering materials is part of choosing a warm roof, and the survey checks the details at the walls and edges.
Because the insulation is outside the structure, the joists and deck stay dry and above the dew point of the room air. A warm roof is also the form that most suits a flat roof replacement where the ceiling below must not be disturbed, since the work is done from above.
How a cold roof is built, and why it needs ventilation
A cold roof has its insulation between the joists, with the deck above a void. The vapour control layer sits on the room side of the insulation, under the plasterboard. Air has to pass through the void, from one side of the roof to the other, to carry away any moisture that gets past the vapour control layer. Without that air path the moisture settles on the cold underside of the deck.
CNC Building Control, a partnership of five councils, publishes a guide to warm roofs; the five are South Norfolk, Norwich City, Broadland, King's Lynn & West Norfolk and Fenland. Plain wording follows: for a warm roof, "No ventilation is required for these types of roofs." For a cold roof, "Ventilation is required for these roofs." Those lines are CNC's own guide, and at a Great Yarmouth or East Suffolk address the route is checked with that council's building control team.
For a cold roof that has a high-resistance (HR) underlay, Marley gives these figures: 25 mm of openings along the eaves at pitches of 15° or less, and 10 mm above 15°. An HR underlay blocks vapour, so the openings are what dry the void. Those figures come from Marley's pitched-roof guidance, so they show the scale of the airflow needed, and a flat roof's ventilation is specified for the roof in question.
How a cold roof is laid out
- Joists carry the deck and the ceiling.
- Insulation sits between the joists with a gap above it.
- A vapour control layer sits on the room side.
- Air enters at one edge and leaves at another.
- The deck and waterproof covering sit above the void.
Condensation: the reason the order matters
Condensation is water that forms when warm, moist air meets a cold surface. A house produces moisture every day through cooking, washing and breathing, and the air carrying it drifts upwards. In a flat roof, if that air reaches a surface cold enough, the moisture turns to liquid and soaks the timber and insulation. Over months this can rot a deck and lift a ceiling, long before anything shows.
A warm roof avoids this by moving the cold surface out of reach. The insulation is above the deck, so the surface that moist air meets stays near room temperature, and the vapour control layer stops most of the air getting that far. A cold roof manages it differently: the vapour layer slows the air down and the ventilation carries off what gets through.
Both builds depend on a vapour control layer without holes, and on sealed joints, edges and penetrations. A light fitting cut through the ceiling, a loft hatch that does not seal or a pipe passing through the layer opens a path for moist air. Our guide to condensation under a flat roof explains the signs and how the cause is traced.
One hole is enough to do damage. Moist air follows the easiest path, so a gap around a single downlight can carry more moisture into a roof than a whole sealed ceiling lets through.
What Part L asks of a flat roof
Part L of the Building Regulations is the energy rule, and it sets how much insulation a flat roof needs. AD L 2021 Table 4.2, which covers new fabric in existing dwellings, gives 0.15 W/(m²·K) for a roof. A roof that is already there and is being renovated is judged against Table 4.3, with a threshold of 0.35 and an improved value of 0.16.
Under paragraph 11.2(d), laying a new waterproof membrane after stripping a flat roof is renovation. If renovation covers more than 50% of the roof's surface, the improved figure is expected for the roof as a whole, where that can be done. Where the full upgrade cannot be done, or would take longer than 15 years to pay back, paragraph 4.13 allows whatever upgrade is feasible inside that payback. AD L 2026 applies from 24 March 2027.
A warm roof meets those figures by choosing boards of enough thickness, and a cold roof by filling the joist depth with insulation. The joist depth can be a limit, and it is one reason a cold roof on a replacement job can fall short without extra insulation under the ceiling. Building control is carried out by the council's building control team or by a registered building control approver, and the council confirms which route applies to your address before work starts.
Terms used in this guide
- U-valueHow much heat passes through the roof
- Vapour control layerSheet that blocks moist air from the room
- VoidThe air gap above insulation in a cold roof
- Tapered boardsInsulation cut to form the fall
Which suits a flat extension
On an extension, the starting point is the room. A new room under a flat roof needs a ceiling height that works, a roof edge that meets the existing wall and eaves cleanly and an insulation standard that satisfies the council's building control. A warm roof gives the most freedom inside, because the insulation does not take up joist depth, and the ceiling can be as high as the structure allows.
A cold roof can suit an extension where the build-up has to stay thin at the edge, such as against a window head or a low eaves line. It needs a clear ventilation path, which means eaves or end openings that stay open and are not blocked by a neighbouring wall, a parapet or a higher roof beside it. Where air cannot get in and out, a cold roof is the wrong choice.
Neither is better on every roof. The survey looks at the joists, the heights at the walls, the existing ventilation and what the council's building control team requires, and then recommends one. Our guide to flat roofs on extensions and dormers covers the junctions in more detail, and the flat roofing hub lists every guide.
The questions that follow from that are practical ones. How high can the roof edge rise before it meets a window head? Is there a parapet or a taller wall that would block air? What does the council's building control team need to see? Those answers shape the choice more than a rule of thumb does.
Choosing between them on a replacement
On a replacement, the existing build-up can decide the choice. A roof built cold can be converted to warm by laying insulation over the old deck, and that raises the roof edge. A roof built warm stays warm. Converting does more than move the insulation: it changes where moisture goes, and the old void has to be dealt with, not left sealed with damp air inside.
Questions to ask a roofer, and what the answers show, are listed below. A roofer who can explain where the vapour control layer goes and why has thought about the roof as a whole. One who says only that a roof is insulated has not. Our written quote follows the survey, gives a single total and names the build-up it prices.
Cost follows the thickness and type of insulation, the deck work, the height changes at the walls and the access. Published figures for the covering are in our flat roof cost guide, and the insulation is part of the one written price.
Where an extension roof is replaced, the ceiling below may be new and well sealed, and the structure old. A survey looks at both, and the written quote names the build-up it prices so you can compare like with like.
Questions to ask about the build-up
- Is the roof proposed as warm or cold?
- Where does the vapour control layer go?
- How is a cold roof ventilated at both edges?
- What U-value does the insulation reach?
- How does the new edge height meet the walls?