The short answer
Droplets form when moist room air meets glazing or a polycarbonate sheet that is colder than the air. Less moisture, more ventilation and a warmer roof surface each reduce it. A badly fitted liner can make it worse by trapping damp air against the cold glazing.
What is happening on the glass
Air holds water vapour, and warm air holds more than cold air. When the warm air in a conservatory reaches a cold surface, it cools there, can no longer hold all of its moisture, and the excess turns to droplets. Breathing, cooking, drying washing, plants and bathing all add moisture to the air.
A conservatory has a great deal of cold surface compared with a normal room. Single-skin glazing and thin plastic sheets are barely warmer than the outside air on a winter night, so droplets form readily on them. How much water forms depends on the room and the weather.
Droplets that run down the glazing bars can stain, soak the seals and promote mould on the frame. That is why condensation is more than a cosmetic problem, and why it is worth treating as a sign of how the room is built.
Fixing it starts with finding out which surface the droplets form on, as that tells you whether the cause is the room's moisture, a cold frame or a failed seal.
Polycarbonate, glass and sealed units
Multiwall polycarbonate can show moisture inside the sheet itself, between the cells, when the end caps and seals fail and damp air gets in. Water trapped in the cells cannot be wiped away, and it points to a breached seal on that sheet. Our guide to replacing polycarbonate roof panels covers what a swap involves.
Sealed glazing units behave differently. Condensation on the inside face of a unit points to room moisture or a cold edge. Misting between the two panes points to a failed seal in the unit, and the unit is replaced and not cleaned. Which of the two you have decides what happens next, which is why a close look is worth more than guessing.
Cold frames matter too. Metal bars that are not thermally broken carry the cold through to the inside, and the line of droplets along every bar gives that away. Thermally broken bars have a barrier in the metal that slows that path.
Where to look for the cause
- Droplets on the inside face of the glazing
- Moisture inside the cells of a sheet
- Mist between two panes of a sealed unit
- Wet lines along every glazing bar
- Black mould at the frame or the eaves
What reduces it
Three levers work together. The first is moisture: keep drying washing and unvented heaters out of the room, and use an extractor in nearby kitchens and bathrooms. The second is ventilation, so damp air has a way out, through trickle vents in the frame, roof vents and opening lights. The third is surface temperature, since a warmer roof surface gives droplets less to form on.
A liner or insulation panel under the old roof can raise the inside surface temperature, but it needs care. A liner that traps damp air against cold glazing can move the problem to where nobody sees it. Our page on insulating a conservatory roof weighs liners, panels and a new roof against one another.
Whichever lever you start with, change one thing at a time and watch the glazing over a cold week, so you know which change made the difference. Notes on the date, the weather and what was done help a later survey.
None of this needs a builder at first. A hygrometer costs little and shows the humidity in the room, so you can see whether the air or the surface is the real problem.
After a solid roof goes on
A new solid roof changes the condensation picture, because the covering is no longer glass. For a cold roof, Marley's BS 5250 figures with a high-resistance underlay are "25mm along the length of the eaves for pitches of 15° or less; 10mm along the length of the eaves for pitches of more than 15°." That underlay is not vapour-permeable. CNC Building Control's warm roof guide says of warm roofs "No ventilation is required for these types of roofs." and of cold roofs "Ventilation is required for these roofs." Which build-up you have decides the answer.
The room still makes moisture after a solid conversion, so it still needs a way for damp air to leave. Our page on ventilating a solid conservatory roof sets out the detail, and the conservatory roofs page links to the rest. A survey of the whole roof comes first, and anything else spotted is pointed out, with one written total price to follow.