Chimney repairs

Do Chimney Waterproofing Sealants Work?

A coating on the brick can slow water entering a sound stack, but it cannot fix a failed joint, flaunching or flashing. Here is where sealants help and where they do harm.

Get a written quote

Call 01493 277103WhatsApp us

A roofer laying new natural slates on a freshly battened roof

The short answer

Sometimes, on sound brickwork. A breathable water repellent can slow the water a good brick takes in. A sealant brushed over open joints, a cracked flaunching or a failed flashing does not stop the leak, and a coating that cannot breathe can hold moisture inside the stack.

Two very different kinds of product

"Sealant" is used loosely for two products that behave differently. A breathable water repellent soaks into the brick or mortar surface and makes it shed water, while still allowing water vapour from inside the wall to pass out. A film-forming coating or sealer sits on the surface as a skin, and the skin blocks liquid water going in and also blocks vapour coming out.

That difference decides almost everything about where a product can be used. A chimney stack is wet on the outside from rain and can be damp on the inside from the flue and from the heat of fires. Brickwork has to be able to dry in at least one direction. Take that away and the water that is already in the brick has nowhere to go but further into the wall, or out through the weakest face, where it pushes off the surface of the brick.

Ask which kind of product is being suggested before agreeing to anything, and ask what the supplier says about breathability for brickwork. A product described only as a sealant, with no mention of vapour, deserves a second question.

Where a coating can help

A breathable repellent has a case on brickwork that is in sound condition and takes up water through its face rather than through a defect. If the bricks are intact, the joints are full and the flaunching, flashings and cap are all doing their jobs, treating the face is a maintenance step that may slow the weathering of the stack.

It is the last step, not the first. The coating works on the surface it is applied to and nothing else, so the stack has to be in a state worth coating. Only a survey from the roof can show it, and ours covers the full roof, so the chimney is judged in its surroundings and anything else we saw is reported plainly.

A treatment is also not permanent. It wears off the surface over time, and it cannot cover a fault that develops underneath it. Tiles on the roof are a separate matter: Marley says high powered jet washes are "not recommended as it can damage the surface of the slate or tile, thus reducing its expected life considerably", which is a reason for care with any pressure cleaning done to prepare a surface for a coating.

Where a sealant goes wrong

The cases where a coating is the wrong answer are the ones that people reach for it in:

  • Open or crumbling joints: the water goes in at the joint, and a coat over the top covers the gap without closing it. Repointing is the repair, as set out in chimney repointing.
  • A cracked flaunching: the sloping mortar bed under the pot lets rain in from above. See chimney flaunching.
  • A lifted or split lead flashing at the roof junction, which no brush-on product can seal. MyJobQuote says correctly installed lead flashing can last for over 80 years, and renewing the lead is the repair.
  • Brick that is already saturated: sealing it in locks the water inside, and frost then does the damage from within.

A sealant applied over a fault can make a leak harder to trace, because the surface looks dry while the water is still entering. Our guide to why a chimney leaks sets out the order a survey follows to find the actual route.

What we do instead

On every chimney the sequence of work runs the same way. We survey the stack and the slopes beside it, find where the water is entering and repair that part. If the brick proves sound once the joints, flaunching and flashings are right, a breathable treatment can be discussed afterwards as an option. The repair is then covered by one written total price. Where the leak has already wetted the loft timbers or the breast inside, the survey says so, and it is raised with you in plain words rather than left for later.

Between surveys, binoculars from the ground show cracked joints, a leaning pot or lead that has lifted at its edge. Date a photograph of what you see: it lets the stack be compared from one season to the next. A photo sent to WhatsApp 07880 284133 is a fair first look, and the main page on chimney repairs lists the other stack problems.

Questions and answers

Can I put a sealant on the chimney myself?

Applying a coating means working at height on the stack, which is a risk of a fall for anyone not equipped for it. There is also the question of whether it helps. If the cause of the damp is a failed flashing or open joint, the coating will not reach it. A survey finds the cause before a product is chosen.

Is a clear waterproofing coating the same as a breathable one?

No. Clear describes how it looks, and says nothing about whether vapour can get through. A breathable repellent lets water vapour pass out of the brick, while a film-forming sealer can block it. Ask the supplier plainly which type the product is and what it says about use on brickwork.

Will a sealant stop the damp patch next to my chimney breast?

Only where the cause is water soaking through sound brick, and a survey has to establish that first. A damp patch also comes from open joints, flaunching, flashings and the flue. Treating the face of the stack while one of those is failing leaves the patch where it is, so the cause is found before the coating.