Call 01493 277103

Skylights & roof windows

Roof Window Flashing Kits

A flashing kit is the set of metal pieces that makes the join between a roof window and the covering around it watertight. This guide explains how kits are matched to slate, plain tile and pantile roofs, and what a recessed fit changes.

Get a written quote

Call 01493 277103WhatsApp us

Conservatory with a solid ceiling and rooflights opening onto the garden

What a flashing kit is made of and what it does

Cutting a roof window into a slope leaves an opening in the covering, and rain running down the slope has to be steered round it. A flashing kit does that. It is a set of formed metal pieces, one for each side of the frame, that overlap each other and the roof covering so water is led past the window and back onto the tiles or slates below. The window maker designs the kit for its own frames, which is why the kit and the window are ordered as a pair.

The pieces have set positions, and the order in which they go on is part of the design. A bottom piece, the apron, lies over the covering below the window and throws water out onto it. Side pieces run down each edge of the frame and tuck under the covering beside it. A top piece sits above the window and sheds water round the frame, passing it to the side pieces. Each lap is arranged so water meets an upward-facing edge only after it has been led away from the opening.

Behind the metal, an underlay collar is dressed round the frame, so that any water that gets beneath the covering is carried to the outside of the window and not into the opening. Inside the roof, an insulation collar packs the space around the frame, and its job is warmth, not weather.

The kit does not work alone. It relies on the covering round it being sound, on the underlay being lapped correctly and on the frame being fixed square. If any one of those fails, the kit is the first thing blamed, even when it has done its job.

Pieces in a kit

  • Bottom apron over the covering below
  • Two side pieces under the covering
  • Top piece to shed water round the frame
  • Underlay collar dressed round the frame
  • Insulation collar around the frame

Flat kits for slate and plain tile

Slates and plain tiles lie flat. Every course sits on the one below with a small overlap, and the surface is close to a single plane. That lets a flat kit work: the side pieces lie on the covering with their edges sitting under the slate or tile beside them, and the courses above run over the top piece.

A flat kit has a stated range of covering thickness, and the roof must fall within it. A thick slate or a double-lapped plain tile roof lifts the surface higher than a single-lap slate, and the kit has to be chosen for that. If the kit's range is too thin for the covering, the pieces stand off the roof and rain is led under their edges instead of past them.

Pitch limits are a separate check. Cupa says BS 5534 sets the floor for natural slate at 20 degrees for a moderately exposed site, with 500mm slates and a 115mm overlap, and Cupa adds that hook fixings are not for any pitch under 25º. A window that goes into a roof near the lower limit relies on its flashing more than one in a steep slope, so the covering's own pitch is confirmed on site.

On a slate roof, a slate that is cracked, delaminated or held by a rusted nail beside the window is a direct route into the opening. A slate roof that is being opened up for a new window is worth looking at as a whole, since the courses beside the opening are the ones that will be lifted and relaid, and our page on how a roof window is installed covers the order of work.

Profiled kits for pantile roofs

A pantile is a curved tile that is laid with an overlap at the side, so the roof surface has a wave in it, with a high point at each roll and a low point in each pan. A flat piece of metal laid on that wave leaves a gap under every roll. That gap is where rain, wind and birds reach the underlay. Profiled kits are the answer: the side pieces are formed to follow the wave, or a flexible lead or aluminium edge is dressed over the roll to close the gap.

Profiled kits come in height ranges, so the kit has to match the depth of the tile. The batten spacing also matters, because the window must sit between battens at the right position for the courses above and below it to be cut and laid neatly. For its clay Old English Pantile, Sandtoft publishes a fixed gauge of 290 mm between battens, and the makers of other tiles list a gauge of their own.

Concrete and clay pantiles differ in profile and in size, and not every profiled kit fits every tile. The answer is not to guess, and a photograph of the tile's underside or edge, with a tape measure beside it, can settle the question. The tile maker's name, if it is known, narrows the choice at once, and so does a spare tile if one was left in the loft or the garage.

When a pantile is cut round the window, the cut tiles must be bedded or mechanically fixed in place, and the courses above must run over the head of the flashing. Marley notes that BS 5534 isn't required by law, yet its 2015 amendments made it clear that mortar could no longer be relied upon as the only means of securing the roof covering. Loose cut tiles beside a window are therefore a fixing question, not a cosmetic one.

Kit shape by covering

Flat kit

  • Slate and plain tile
  • Lies flat on covering
  • Check thickness range

Profiled kit

  • Pantile and rolled tile
  • Follows the wave
  • Check tile depth range

Recessed fitting and what it changes

A standard fit sets the window frame on top of the rafters, so the glass stands a little above the plane of the covering. A recessed fit drops the frame down between and into the rafter line, so the glass sits closer to the surface of the tiles. It looks tidier from the street and gives a smaller upstand round the glass.

A recessed fit needs a kit made for it. The pieces are shaped to a lower frame, and the underlay and the insulation collar are dressed differently. A recessed window with a standard kit leaves a gap that water can reach. Do not swap a standard kit for a recessed window to save time; the two are not interchangeable.

Recessing has structural consequences. The frame is lowered into the roof structure, which can mean the rafters or the support timbers are cut and trimmed to suit, and cutting rafters is work that needs a structural check and, depending on the roof, the attention of building control. Our guide to Velux window replacement covers why a replacement window is checked against the existing opening and its kit.

The look of the roof from the road is a reason some people choose a recessed fit, and it can matter for planning too. Class C of the General Permitted Development Order limits how far a roof light may stand out from the original slope to 0.15 metres, so how proud the frame stands is a question to settle with the council before work starts, along with flats, listed homes and Article 4 directions.

Lead, aluminium and other kit materials

Aluminium kits are factory-formed and finished in a colour to suit the covering, because the metal is light and takes a shaped profile well. Lead is the older alternative: it is soft, so it can be dressed by hand round a roll or a cut tile and shaped on the roof where the covering is irregular.

Lead is graded by code. Leadworx, a maker of lead flashing, grades lead sheet from code 3 to code 8, with the grades compliant with BS EN 12588. Its view is that code 4 has become the standard choice for general flashing work, while each detail's specification names the code to use.

MyJobQuote says correctly installed lead flashing can last for over 80 years. That statement is about lead flashing in general and depends on correct installation, so it is the work and not the metal alone that earns that life. For an aluminium kit, the maker's own literature gives the life, and a kit with split joints or lifted edges needs replacing whatever its age.

Material also affects appearance. Bright aluminium stands out against old tiles, while a powder-coated finish in a matching colour blends in. Lead weathers to a dull grey that sits comfortably against slate. The cost differences between the two vary with the job, which is why they belong on the written quote and not in a general rule.

Getting the kit right, and the quote

Ordering the wrong kit is easy, because the choice rests on four facts: the window size and model, the covering, whether the fit is standard or recessed, and whether the window stands alone or sits in a group. Windows grouped in a row or stacked in a column need connecting pieces, and a group kit is not a set of single kits pushed together.

The most reliable way to settle those facts is to look at the roof. A survey checks the tile or slate and its thickness, the pitch, the batten gauge, the rafters and the state of the covering round the opening. For a replacement, it also checks the existing window's size and fit. If you have a window now, the label on its frame carries its model, and a photograph of it saves guesswork.

A kit that leaks can have any of several fitting faults: pieces out of order, a kit for the wrong covering, a bent piece, a missing underlay collar or a fixing that has pulled. The metal itself may be perfectly sound. Our skylights and roof windows hub gathers the guides on each of these topics.

The survey covers the whole roof before any pricing, so a kit is chosen knowing what condition the covering is in. It also gives us the chance to mention anything else that caught our eye up there, such as a ridge or a gutter that needs attention. After that comes a written price, a single total for whatever the survey finds needs doing. A WhatsApp photo of the window and the tiles around it gets a first view from us.

Questions and answers

Can I use a flat flashing kit on a pantile roof?

No. Pantiles are laid with a rolled surface, and a flat kit leaves a gap under every roll that lets rain and wind reach the underlay. A kit made for profiled tiles, or lead dressed over the rolls, closes that gap. The tile's depth and make decide which kit fits.

Is a recessed roof window fitted with a different kit?

Yes. A recessed window sits lower in the roof structure, so its flashing pieces, underlay dressing and insulation collar differ from a standard fit. A standard kit on a recessed window leaves a gap that water can reach, so the kit is ordered to match the way the window will be fitted.

How long does a flashing kit last?

There is no single answer for every kit. MyJobQuote says correctly installed lead flashing can last for over 80 years, but that depends on how it was fitted, and an aluminium kit's life is for its manufacturer to state. A kit that has bent, split or pulled from its fixings is replaced instead.

Does a new roof window need a new flashing kit?

A replacement window comes with a kit made for it, and old pieces cut for another model may not fit the new frame. The survey checks the old kit, the covering and the underlay before anything is reused, because reusing worn pieces is a quick way to a leak, and a new frame in an old kit is only as watertight as the old kit.