A roof window in a loft bedroom can be the way out in a fire if its opening meets set sizes. Here are the Approved Document B figures, how they combine and when a window is not enough.

Get a written quote

Call 01493 277103WhatsApp us

Red interlocking roof tiles running up to a small dormer

The short answer

An escape roof window in England needs an openable area of at least 0.33 m², at least 450 mm high and 450 mm wide, and the lowest edge of the opening no more than 1100 mm above the floor. Windows serve storeys up to 4.5 m above ground; higher up, a stair or another route is needed.

The three measurements an escape window has to meet

Approved Document B, volume 1, is the fire safety guidance for dwellinghouses in England. Paragraph 2.10 describes the emergency escape window and gives three limits. The first is area: a minimum of 0.33 m². The second is shape: a minimum height of 450 mm and a minimum width of 450 mm. The third is position: the bottom of the opening may be at most 1100 mm up from the floor.

All three apply together. The area figure and the shape figure have to be read together, and a square opening shows why. A clear opening 450 mm wide and 450 mm high is only about 0.2 m², well short of 0.33 m², so a window that scrapes past the minimum in each direction still fails on area. For a width of 450 mm, the height has to be about 733 mm to reach 0.33 m², and a wider opening needs less height.

The measurements are taken on the part of the window that opens, not on the frame or the glass as supplied. A large roof window with a deep frame and a narrow sash can pass on its catalogue size and fail on its real openable area. For that reason the check is made against a real window, in the opening angle it actually reaches, and with a tape measure.

Paragraph 2.10 in short

  • Openable area: at least 0.33 m²
  • Height: at least 450 mm
  • Width: at least 450 mm
  • Bottom of the opening: no more than 1100 mm up
  • All four hold together

Why roof windows need extra thought

The 1100 mm limit is simple to meet in a wall and awkward in a roof. A roof window sits on a slope, so its position is set by the rafters and by where the floor of the room meets the roof. A window placed high on the slope to catch the light, or one over a knee wall, can have its lowest openable edge well above 1100 mm,, and climbing out would be a struggle.

The way the sash opens matters too. A top-hung window swings out from the bottom edge and leaves a gap below the sash. A window that pivots turns about a bar across its middle, so the opening divides into one gap above the bar and one below it. Which gap counts, and what clear area each leaves, depends on the model, so the measurement is taken on the actual window at its actual angle.

The size of the room below counts as well. An escape window serves the person in the room, so a person has to be able to reach the sill, step through and reach the roof or a safe place beyond it. Whether the roof outside offers a safe place to go is a question for building control, not one a window size alone can answer.

When a window is not enough

A window does its job only up to a limit. Paragraph 2.2 deals with storeys that are a maximum of 4.5 m above ground level. For those, the guidance accepts an escape window, an external door, or a way straight onto a protected stairway. Higher than that, a window is not the answer.

Where a loft conversion creates a storey more than 4.5 m above ground, paragraph 2.5 calls for either a protected stairway or an alternative escape route. The first choice is a stair walled off with fire-resisting construction rated REI 30 at the least on every storey. The second choice walls off the top storey from the floors beneath to that same rating and gives it a separate exit of its own. Open-plan layouts get one further option in paragraph 2.23, which is sprinkler protection.

There is no rule of thumb that every loft needs a protected stair. The route depends on the height of the new storey and the layout, which is why it is settled with building control at the start. For the rest of the rules on a roof window, see the guide to Building Regulations for roof windows.

Choosing the window and checking it

Start from the room and not from the catalogue. Measure how high the floor of the loft room is above the ground outside, work out where the sill of the window would fall, and check the floor to the lowest openable edge against 1100 mm. Then ask the supplier for the clear opening dimensions of the model at its widest opening, not the overall frame size, and write them down against the three limits so the comparison is plain.

If a size is close to the limit, a different model or a lower position may be the fix, and a different position can mean altering the rafters. The structure rules are in the guide to how a roof window is installed.

At Total Roofing Great Yarmouth we check the building control route for a loft window with the council before work starts, and the figure you are given afterwards is a single written total.

Questions and answers

Does every loft bedroom need an escape window?

Paragraph 2.2 of Approved Document B gives an emergency escape window as one of the routes for storeys up to 4.5 m above ground level, the other being direct access to a protected stairway. Whether a particular loft needs one depends on its height and layout, so ask building control for the route before the design is fixed.

Can a fixed rooflight be an escape window?

No, because the openable area is what counts. Paragraph 2.10 sets its figures for the part that opens, so a fixed unit has no openable area at all. A rooflight can bring daylight to a room, but the escape has to come from an opening part that meets the three limits, or from a stair or alternative route.

Is a bigger roof window always safer for escape?

Not by itself. The limits are a minimum area, a minimum height, a minimum width and a ceiling on the height of the bottom of the opening, so a large window set too high can still fail the last one. The figure that matters is the clear opening at the position it will sit, taken from the finished floor level.