Call 01493 277103

Flat roofing

Liquid Flat Roof Coatings

A liquid coating is rolled or brushed onto a flat roof and sets into a jointless skin. Here is what it can go over, why the surface beneath matters more than the product and when it is advised against.

Get a written quote

Call 01493 277103WhatsApp us

A glass roof lantern on a flat-roofed rear extension

The short answer

A liquid flat roof coating is a resin-based product put on wet over a prepared roof, where it sets as one unbroken waterproof film. It suits a sound, dry surface that is cleaned, repaired and primed first. It does not rescue a wet, soft or failed roof, because it takes on every fault beneath it.

What a liquid coating is

A liquid coating is applied as a fluid and sets on the roof, in contrast to a felt or rubber sheet that is rolled out in lengths. Because it flows, it can run round pipes, rooflights, upstands and awkward corners without cut joints, and on curing it forms a single skin across the surface.

Products differ in their chemistry and in how they are applied, and each maker issues its own data on what it bonds to and how it should be laid. Some are brushed or rolled in two coats with a reinforcing fabric bedded between them at laps, cracks and details, so the skin is held together where the roof moves. Others are sprayed or applied in a thicker layer.

The point to understand is that a coating is only a waterproof skin. It adds no strength to a weak deck and no insulation to a cold one, so it answers a covering that is failing but does nothing for a structure that is.

Which surfaces it can go over

A coating bonds to the surface beneath it, so that surface is the first thing a roofer reads. Depending on the product, the base might be an existing felt roof, a concrete deck, a metal sheet or a GRP roof. The maker's instructions say which and what primer is required.

A base has to be clean, dry and firmly attached. Moss, algae, dirt and loose granules are removed, defects are made good and a primer is applied where the product calls for one. Skipping that stage is how a coating comes to peel.

  • Felt with blisters, splits or soft patches needs those faults dealt with first, since a coating will not stop a pocket of moisture from lifting it. Our page on flat roof repairs covers how those are mended.
  • A deck that gives underfoot, or boards with rot, needs replacing, and a coating will not stiffen them.
  • A roof where water stands needs its falls looked at, because coatings do not correct ponding.
  • A wet surface at the time of application locks that moisture in beneath the film.

When a coating is not the answer

If the felt or deck below is wet, if the insulation is sodden or if the covering has failed over a wide area, coating over the top seals the damage in. The same applies to a roof that is already condensing from the inside: a new skin above does nothing about vapour rising from the rooms below.

Where a garage or outbuilding roof is made of corrugated sheets, HSE's advice is "If the building was built or refurbished before 2000, assume that there is asbestos in it", and its guidance A14 says "AC roofs are always fragile". Do not walk on such a roof or start any coating work on one. Get it identified first, and our page on asbestos disposal in Norfolk and Suffolk sets out the rules.

There is also the Building Regulations side. A new waterproof layer on a flat roof can bring in the Part L renovation rules, so the route is one to settle with the council's building control team or a registered building control approver before work starts, rather than assuming a coating is exempt.

On a roof that has little life left, a coating can postpone a replacement for a time without removing the need for one, and the survey says which case you are in. That is a fair question to put to any firm offering a coating.

Getting a coating looked at

Send photographs of the surface, taken from a safe position, to 07880 284133 on WhatsApp or ring 01493 277103. They show cracks, blisters and moss, though not the dampness underneath, so the survey tests the surface properly, with moisture checked at any suspect patch and the deck pressed for soft spots before a coating is even discussed. It takes in the entire roof, edges and outlets as well as the area you are worried about, and anything else we notice is named in the findings.

Once the survey is complete, you are given a single price in writing. The wider flat roofing section sets out the alternatives, including EPDM rubber roofing, so you can weigh a coating against replacing the covering. Ask what the coating is bonded to, how the roof will be prepared and how the details at upstands and outlets are finished, so two offers can be compared on the same terms.

Questions and answers

Will a coating stick to old felt?

Sometimes, if the felt is dry, firmly bonded and free of blisters and splits, and if the product's maker allows it on that base. A felt roof with wet patches or hollow areas has to be repaired first, because a coating takes on every fault beneath it. The survey looks at the felt before a coating is offered.

Does a liquid coating fix a leaking flat roof?

Only if the leak comes from the surface. A coating over a leaking, wet or sagging roof seals water in rather than out. The survey finds where the water is entering, and the leak is repaired before anything is applied. Once the roof is sound, a coating may be a sensible way to renew the waterproof layer.

Do I need Building Regulations approval for a roof coating?

Possibly. A new waterproof layer on a flat roof can fall under the Part L renovation rules, depending on the work. Ask the council's building control team, or a registered building control approver, which route applies before the work is booked, as the answer depends on the roof and the product.

Get a written quote

Tell us about your roof

Hand dressing a lead ridge roll with a wooden bossing stick

10-year workmanship guarantee, in writing

Call WhatsApp Written quote